Personal tools

Fast and Accurate Multiclass Inference for Brain–Computer Interfaces

From iis-projects

Jump to: navigation, search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.



Fast and Accurate Multiclass Inference for MI-BCIs Using Large Multiscale Temporal and Spectral Features =

Abstract

Accurate, fast, and reliable multiclass classification of electroencephalography (EEG) signals is a challenging task towards the development of motor imagery brain-computer interface (MI-BCI) systems. We propose enhancements to different feature extractors, along with a support vector machine (SVM) classifier, to simultaneously improve classification accuracy and execution time during training and testing. We focus on the well-known common spatial pattern (CSP) and Riemannian covariance methods, and significantly extend these two feature extractors to multiscale temporal and spectral cases. The multiscale CSP features achieve 73.70±15.90% (mean± standard deviation across 9 subjects) classification accuracy that surpasses the state-of-the-art method [1], 70.6±14.70%, on the 4-class BCI competition IV-2a dataset. The Riemannian covariance features outperform the CSP by achieving 74.27±15.5% accuracy and executing 9x faster in training and 4x faster in testing. Using more temporal windows for Riemannian features results in 75.47±12.8% accuracy with 1.6x faster testing than CSP.

Keywords

EEG, motor imagery, brain–computer interfaces, multiclass classification, multiscale features, SVM

Status: Completed

Semester thesis by Michael Hersche and Tino Rellstab
Supervision: Abbas Rahimi, Lukas Cavigelli, Pasquale Davide Schiavone