User contributions
From iis-projects
(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)
- 15:15, 22 May 2018 (diff | hist) . . (+16) . . High performance continuous-time Delta-Sigma ADC for magnetic resonance imaging (→Links)
- 15:13, 22 May 2018 (diff | hist) . . (-46) . . High performance continuous-time Delta-Sigma ADC for magnetic resonance imaging (→Links)
- 15:09, 22 May 2018 (diff | hist) . . (+620) . . Switched-capacitor power amplifier for IoT mobile communications: design of signal processing path (→Short Description)
- 15:07, 22 May 2018 (diff | hist) . . (+620) . . Ultra-low power sampling front-end for acquisition of physiological signals (→Short Description)
- 15:06, 22 May 2018 (diff | hist) . . (+620) . . Ultra-low power transceiver for implantable devices (→Short Description)
- 15:04, 22 May 2018 (diff | hist) . . (-50) . . Ultra-low power transceiver for implantable devices (→Short Description)
- 14:27, 22 May 2018 (diff | hist) . . (+1,753) . . N Ultra-low power transceiver for implantable devices (Created page with "==Short Description== Beside being small low power consumption is a key asset for implantable devices. This is often in conflict with performance as the latter is commonly lin...")
- 10:34, 22 May 2018 (diff | hist) . . (+22) . . Switched-capacitor power amplifier for IoT mobile communications: design of signal processing path (→Short Description)
- 10:32, 22 May 2018 (diff | hist) . . (+1,882) . . N Switched-capacitor power amplifier for IoT mobile communications: design of signal processing path (Created page with "==Short Description== Mobile communication transmitters need to have a maximum output power in the order of 1W to reliably transmit data over distances of multiple kilometers...")
- 10:01, 22 May 2018 (diff | hist) . . (+1,827) . . N Ultra-low power sampling front-end for acquisition of physiological signals (Created page with "==Short Description== Beside being small low power consumption is a key asset for implantable devices. This is often in conflict with performance as the latter is commonly lin...")
- 09:28, 22 May 2018 (diff | hist) . . (0) . . File:MRISystemBlkDgr.png (Burger uploaded a new version of File:MRISystemBlkDgr.png) (current)
- 09:12, 22 May 2018 (diff | hist) . . (+24) . . High performance continuous-time Delta-Sigma ADC for magnetic resonance imaging (→Short Description)
- 09:10, 22 May 2018 (diff | hist) . . (0) . . m High performance continuous-time Delta-Sigma ADC for magnetic resonance imaging (Burger moved page High performance continous-time Delta-Sigma ADC for mobile communications to High performance continous-time Delta-Sigma ADC for magnetic resonance imaging)
- 09:10, 22 May 2018 (diff | hist) . . (+92) . . N High performance continous-time Delta-Sigma ADC for mobile communications (Burger moved page High performance continous-time Delta-Sigma ADC for mobile communications to High performance continous-time Delta-Sigma ADC for magnetic resonance imaging) (current)
- 17:06, 22 December 2017 (diff | hist) . . (+1) . . Inductive Charging Circuit for Implantable Devices
- 16:58, 22 December 2017 (diff | hist) . . (0) . . Inductive Charging Circuit for Implantable Devices
- 16:56, 22 December 2017 (diff | hist) . . (0) . . N File:Schatz Figure1.jpg (current)
- 16:56, 22 December 2017 (diff | hist) . . (+2,592) . . N Inductive Charging Circuit for Implantable Devices (Created page with "thumb|400px ==Short Description== Implantable devices have seen a large growth in the past years. For humans pacemakers are most common, but more r...")
- 18:48, 21 December 2017 (diff | hist) . . (+32) . . CMOS power amplifier for field measurements in MRI systems
- 18:46, 21 December 2017 (diff | hist) . . (0) . . N File:MRISystemBlkDgr.png
(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)